Others : https://iopscience.iop.org/article/10.1088/1755-1315/267/4/042088/pdf DOI : 10.1088/1755-1315/267/4/042088 |
|
学科分类:环境科学(综合) | |
来源: IOP | |
【 摘 要 】
ABAQUS software was first used to study the structure behaviour of steel-to-concrete connection by post-installed anchorage under cyclic loading. Three types of embedment depth 25d, 20d and 15d were considered. Based on previous simulation results of earthquake and fire, it can be concluded that the seismic performance of steel-to-concrete connection by post-installed anchorage is strongly related to the rotation angle 0 of steel beam. The heat analysis results indicate that the fire resistance of post-installed connection after 2 hours exposure could meet the requirement of related codes. Based on the simulation results mentioned above, a performance-based design conception with four performance levels has been provided to guarantee structure safety under the combined action of earthquake and fire. According to the principle of performance-based methodology, rotation angle 0 of steel beam and fire resistance rating T are chosen as critical index for performance evaluation. Among the 4 levels of performance, Level 1 has the highest specification for disaster protection. To achieve the performance level 1, the thickness of fire protection layer should not be less than 45 mm, and the embedment depth should be 25d at least.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Performance-based design method of steel-to-concrete post-installed connection under combined action of earthquake and fire | 418KB | download |