会议论文详细信息
4th International Conference on Energy Equipment Science and Engineering
PFC Performance Evaluation Based on Modeling and Identification of Unit's Main Parameters
Li, Jun^1^2 ; Qian, WenXiao^2 ; Meng, XiangRong^1 ; Liu, WeiMing^2 ; Xiang, Song^3
State Grid Shandong Electric Power Research Institute, Jinan, China^1
State Grid East Inner Mongolia Electric Power Research Institute, Hohhot, China^2
State Grid East Inner Mongolia Electric Power Supply Co. Ltd., Hohhot, China^3
关键词: Main parameters;    Main steam pressures;    Performance indices;    Power grid frequencies;    Primary frequency control;    Rotational speed;    Technology standards;    Thermal power units;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/242/3/032015/pdf
DOI  :  10.1088/1755-1315/242/3/032015
来源: IOP
PDF
【 摘 要 】

The rapid development of new energy brings great challenges to the frequency control of power grid, and the early adjustment of power grid frequency mainly depends on the PFC(primary frequency control) function of thermal power units. In view of the limitations of traditional PFC performance evaluation, combined with the grid's PFC technology standards, through the history of thermal power unit operation data, by selecting appropriate PFC data section, the mathematical model based on rotational speed, the main steam pressure and actual power was established. The performance index of PFC can be calculated from the model step response. The simulation and practical operation results show that the proposed method effectively represents the PFC performance of the unit and provides one reliable means for power grid to monitor the PFC performance.

【 预 览 】
附件列表
Files Size Format View
PFC Performance Evaluation Based on Modeling and Identification of Unit's Main Parameters 677KB PDF download
  文献评价指标  
  下载次数:18次 浏览次数:25次