4th International Conference on Energy Equipment Science and Engineering | |
Research on Real-Time Database Recovery Method of Smart Grid System Based on IEC61970 Standard | |
Lin, Shuqing^1 ; Maalla, Allam^1 ; Wu, Guangyu^1 | |
Research Institute of Open Data Commercial Application, School of Information Technology and Engineering, Guangzhou College of Commerce, Guangzhou | |
511363, China^1 | |
关键词: Data integrity; IEC61970 standard; Malicious transaction; Power grid dispatching; Power grid system; Real-time database; Real-time database management systems; Smart grid systems; | |
Others : https://iopscience.iop.org/article/10.1088/1755-1315/242/2/022046/pdf DOI : 10.1088/1755-1315/242/2/022046 |
|
来源: IOP | |
![]() |
【 摘 要 】
Real-time database management system plays an important role in power grid system. With the increasing development of smart grid, the problem of data integrity security in real-time database has attracted more and more attention. Research on real-time database recovery Method of Smart Grid system is based on IEC61970 standard using RFID algorithm. After the data integrity is destroyed, it takes only a rollback malicious transaction, without having to roll back all transactions, the transaction conflict caused by the transaction revocation can be avoided, that can improve the survivability of real-time databases, protect the integrity of the real-time database of smart grids, and improve power grid dispatching system. Therefore, real-time database recovery Method plays an important role in power grid dispatching system.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Research on Real-Time Database Recovery Method of Smart Grid System Based on IEC61970 Standard | 571KB | ![]() |