会议论文详细信息
29th IAHR Symposium on Hydraulic Machinery and Systems
Transfer of transient conditions from prototype to closed-loop model test rig
Junginger, J.^1 ; Riedelbauch, S.^1 ; Kirschner, O.^1
Institute of Fluid Mechanics and Hydraulic Machinery, University of Stuttgart, Pfaffenwaldring 10, 70569, Germany^1
关键词: Closed loop models;    Closed loop test;    Power variations;    Real power plants;    Reversible pump-turbine;    State of the art;    Transient conditions;    Transient process;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/240/8/082010/pdf
DOI  :  10.1088/1755-1315/240/8/082010
来源: IOP
PDF
【 摘 要 】

This paper describes a method for determining the sequence of transient model test experiments in a closed loop test-rig, using previous 1D-simulations. A real power plant with reversible pump turbine in the Austrian Alps serves as baseline. A fast transition with load rejection and guide vane closing has been simulated, as it is state of the art. Furthermore, it was assumed that this power plant also has a full size frequency converter for fast transition from pump mode to turbine mode and vice versa applying linear speed variation. These simulation results were transferred to the scaled model size via similarity laws. Of particular importance is the choice of model to prototype speed ratio whose influence has been studied more closely. Subsequently, the transient processes are simulated in a closed loop test-rig. The simulations are controlled by a temporal power variation of the service pump. An iteration loop with optimizer has adapted the power in order to achieve similar conditions as in the prototype simulation. The findings of the pump behavior can then be used for the transient model test experiments.

【 预 览 】
附件列表
Files Size Format View
Transfer of transient conditions from prototype to closed-loop model test rig 1418KB PDF download
  文献评价指标  
  下载次数:15次 浏览次数:10次