29th IAHR Symposium on Hydraulic Machinery and Systems | |
Study on intense vibration of local structures of Zhanghewan pumped-storage powerhouse | |
Li, J.W.^1 ; Gu, Z.F.^2 ; Zhu, H.F.^2 ; Yu, J.X.^1 ; Ouyang, J.H.^1 | |
China Institute of Water Resources and Hydropower Research, Beijing | |
100048, China^1 | |
Hebei Zhanghewan Pumped Storage Power Generation Co. Ltd., HEBEI | |
050300, China^2 | |
关键词: Excitation sources; Hydropower stations; Local structure; Operation personnel; Pumped Storage; Research process; Safe operation; | |
Others : https://iopscience.iop.org/article/10.1088/1755-1315/240/8/082008/pdf DOI : 10.1088/1755-1315/240/8/082008 |
|
来源: IOP | |
【 摘 要 】
Vibration of the powerhouse has an important influence on safe operation of hydropower station and health of operation personnel. In the present paper, intense vibration of local structures of Zhanghewan pumped-storage powerhouse is studied, and the reason of intense vibration is illustrated through analyzing the main excitation sources and the natural frequencies of local structures. The revelation from the research process and conclusions is that the entirety resonance of the powerhouse should be avoided absolutely during the process of design, and the resonance between local structures and the main excitation sources should be avoided as well.