29th IAHR Symposium on Hydraulic Machinery and Systems | |
A novel volute design for reducing radial force in pump and PAT | |
Arani, Hamed Alemi^1 ; Fathi, Mohammad^1 ; Raisee, Mehrdad^1 ; Nourbakhsh, Seyed Ahamd^1 | |
Hydraulic Machinery Research Institute, School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 14395-515, Tehran, Iran^1 | |
关键词: Computation grid; K-Omega turbulence model; Low specific speed centrifugal pump; Numerical results; Operating modes; Reynolds stress; Second order upwind scheme; Transport equation; | |
Others : https://iopscience.iop.org/article/10.1088/1755-1315/240/4/042004/pdf DOI : 10.1088/1755-1315/240/4/042004 |
|
来源: IOP | |
【 摘 要 】
In the current paper a novel volute design is proposed to reduce the radial force of a low specific speed centrifugal pump in both direct and reverse modes. First, the fluid flow in the pump in both modes was simulated by utilizing commercial CFD software. For evaluation of unknown Reynolds-Stresses, the k-ω turbulence model was employed. The nonlinear convective terms in all transport equations were approximated by the second-order upwind scheme. The unstructured computation grid with 1.75×106 cells was used for the computation. The numerical results were verified against the measured data and acceptable agreement between them was found. Numerical results showed that changing the operating mode of a pump from direct to reverse increases the flowrate, head and power in the BEP but deteriorates the radial force. Therefore, a novel volute based on BEP flowrate of PAT was proposed. In pump mode, it was found that although this novel design decreases the efficiency in low flowrates slightly, it increases the head and efficiency in high flowrates considerably. Interestingly, the radial force is decreased significantly and the point of minimum radial force is shifted to 125% of BEP flowrate. The comparison of PAT performance with the original volute and the novel one revealed that the new design leads to lower head and power in all flowrates. However, this design provides more uniform pressure distribution around the impeller periphery and thus reduces the radial force.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
A novel volute design for reducing radial force in pump and PAT | 791KB | download |