会议论文详细信息
4th Asia Conference of International Building Performance Simulation Association
Study of influence of shading louvers on wind characteristics around buildings under different wind directions
土木建筑工程
Zheng, J.W.^1 ; Tao, Q.H.^1 ; Li, L.^1
College of Mechanical and Energy Engineering, Jimei University, Xiamen, China^1
关键词: Airflow patterns;    Building envelopes;    Building surface;    Complex buildings;    Computational fluid dynamics methods;    Cross ventilation;    Wind characteristics;    Wind pressure coefficient;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/238/1/012031/pdf
DOI  :  10.1088/1755-1315/238/1/012031
学科分类:土木及结构工程学
来源: IOP
PDF
【 摘 要 】

In this paper, the wind characteristics on building with single-sided louvers under different wind directions were studied by using computational fluid dynamics (CFD) method. The RNG k- model was employed to establish the different outdoor airflow fields under different rotation angles θ of louvers. To investigate the wind pressure on facades, wind pressure coefficient C P was introduced and average surface difference ΔC P was applied to evaluate wind-induced cross ventilation between the shaded and the opposite building surfaces. Results show that airflow pattern around the studied building is highly dependent on the building envelope under shading conditions due to obstruction and diversion of louvers. In general, the larger rotation angle of louvers contributed to more differences in average surface C P under both normal and parallel wind directions. Shading louvers lead to an increase in ΔC P for parallel approach flow and a decrease in ΔC P for perpendicular approach flow. In simulations of this study, it could be seen that ΔC P decreases 0.01 (1.6%) for θ = 0? and 0.15 (18.0%) for θ = 60? under normal wind direction, while ΔC P increases 0.05 (436.1%) for θ = 0? and 0.15 (1393.5%) for θ = 60? under parallel wind direction. The results elucidates that a larger rotation angle can affect wind-induced cross ventilation more strongly. What's more, the locations of minimum and maximum C P on some facades moved obviously after shading and turning up rotation angle. This study indicates that the influence of complex building envelopes like shading louvers, should be considered in ventilation design.

【 预 览 】
附件列表
Files Size Format View
Study of influence of shading louvers on wind characteristics around buildings under different wind directions 1019KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:17次