In order to compare the design of hybrid energy systems for on-grid and off-grid applications, a university dormitory in central China is selected and investigated to achieve the target of a zero energy dormitory. The building is modeled in DeST and hybrid system design optimization is performed in HOMER. Results show that the on-grid hybrid system under time-of-use rate policy is much more economic than that under single rate policy for on-grid case. The total net present cost is 230,534 $ and the levelized cost of energy is 0.124 $/kWh. The off-grid system with generators is more economical than system without them, and the cost is found to be about 6 times than on-grid system. Sensitivity analysis is performed by considering sell-back price and diesel price, it is found that NPC and COE can be increased by 9.7% and 12.7% for the decreased sell-back price and doubled diesel price respectively.

【 预 览 】
附件列表
Files Size Format View
Comparative analysis of hybrid systems for on-grid and off-grid applications in central China: Case study of university dormitory in Ma'anshan 719KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:14次