会议论文详细信息
Proceedings of the 3rd International Conference on Science and Technology Applications in Climate Change
Disposable bismuth-based electrodes for heavy metal ion detection
生态环境科学
Gupta, Sandeep^1 ; Sapna, K.M.^2 ; Ray, Kanad^3 ; Kothari, S.L.^1 ; Awasthi, Kamlendra^2 ; Kumar, Manoj^2
Amity Institute of Biotechnology, Amity University Rajasthan, Kant Kalwar, NH-11C, Jaipur, Rajasthan
303007, India^1
Department of Physics, Malaviya National Institute of Technology, JLN Marg, Jaipur, Rajasthan
302017, India^2
Amity Institute of Applied Sciences, Amity University Rajasthan, Kant Kalwar, NH-11C, Jaipur, Rajasthan
303007, India^3
关键词: Microplates;    Mixed oxide;    Polycrystalline;    Potentiostatic electrodeposition;    Stripping voltammetry;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/228/1/012014/pdf
DOI  :  10.1088/1755-1315/228/1/012014
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

This work presents the efficacy of bismuth-based mixed oxide nanosructures for heavy metal ion detection. Four samples with varying proportions of Na3BiO4, Bi2O3 and Na2O were synthesized using potentiostatic electrodeposition. X-ray diffraction (XRD) indicates the presence of poly-crystalline Na3BiO4 and Na2O in sample 1 while presence of poly-crystalline Na3BiO4 and Bi2O3 were seen in samples 2 and 3. Poly-crystalline Bi2O3 was seen in sample 4. Scanning electron microscopy (SEM) showed the presence of microplates of varying shapes and sizes with an average thickness

【 预 览 】
附件列表
Files Size Format View
Disposable bismuth-based electrodes for heavy metal ion detection 3077KB PDF download