会议论文详细信息
International Conference on the Sustainable Energy and Environmental Development
Analysis of energy recovery from surplus water pressure of municipal heat distribution network
生态环境科学
Borkowski, D.^1 ; Wgiel, T.^1
Institute of Electromechanical Energy Conversion, Cracow University of Technology, Warszawska 24, Cracow
31-155, Poland^1
关键词: Electrical generators;    Energy conversion systems;    Heat distribution network;    Mechanical pressure;    Pressure reducing valves;    Recovered energy;    Water parameters;    Water pressures;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/214/1/012014/pdf
DOI  :  10.1088/1755-1315/214/1/012014
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

The correct operation of a heating network system depends on appropriate water parameters of a network, especially a water pressure. The heating source provides the water pressure depending on the worst conditioned water main in the network. The structure of the water heating network depends largely on the landform features and, in many situations, a pressure zone with the pressure reducing valves is required. This excess pressure gives an opportunity for energy recovery during reduction of the pressure from the system. This can be done by substituting the existing mechanical pressure reducing valve by a water turbine combined with an electrical generator. In the paper, an example of a heating system is analysed and possible recovered energy is calculated assuming a specific value of energy conversion system efficiency. The real tests of the prototype reducer showed possibilities to achieve satisfying efficiency of an energy conversion. The presented economic analysis confirmedpotential of the proposed system.

【 预 览 】
附件列表
Files Size Format View
Analysis of energy recovery from surplus water pressure of municipal heat distribution network 789KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:13次