会议论文详细信息
2019 2nd International Conference on Composite Materials Science and Technology
DC-link voltage feedforwarded interpolation error compensation method for field weakening operation region of look-up table based PMSM drive
Lee, Jung-Hyo^1
Kunsan National University, Electrical Engineering Department, Gunsan
54150, Korea, Republic of^1
关键词: Control characteristics;    Current reference generation;    Feed-forward controllers;    Field weakening control;    Field weakening operation;    Interpolation error;    Interpolation method;    Permanent magnet synchronous machines;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/600/1/012024/pdf
DOI  :  10.1088/1757-899X/600/1/012024
来源: IOP
PDF
【 摘 要 】

This paper proposes field weakening control method of the look-up table based permanent magnet synchronous machine (PMSM) with interpolation error compensation. The look-up table based control method has robust control characteristic than other control methods which use linear controller for current reference generation. However, it is impossible to store all current references under all circumstances for torque commands. General look-up table based control method using two input parameters, in order to mitigate the effect of discretely stored data, two-dimension-interpolation method (2D-Interpolation) is used for linear interpolating between discontinuous data. However, due to the current trajectories of PMSM are generally ellipsoidal, the error is occurred between linearly interpolated and controllable current references. This paper proposes a method to compensate this interpolation error using feedforward controller for fast compensation. The improvement of proposed method is verified by experiment and simulation.

【 预 览 】
附件列表
Files Size Format View
DC-link voltage feedforwarded interpolation error compensation method for field weakening operation region of look-up table based PMSM drive 842KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:13次