会议论文详细信息
| 2019 International Conference on Advances in Materials, Mechanical and Manufacturing | |
| Early Faults and Characteristics of Large Capacity Non-salient Pole Synchronous Electric Machines | |
| 材料科学;机械制造 | |
| Wang, Andong^1 ; Wang, Jihao^1 ; Li, Junqing^2 ; Ma, Yangshuo^2 ; Sun, Fuchun^1 | |
| State Grid Shandong Electric Power Research Institute, Jinan | |
| 250002, China^1 | |
| School of Electric and Electronics Engineering, North China Electric Power University, Baoding | |
| 071003, China^2 | |
| 关键词: Complicated structures; Early fault; Economic loss; Non-salient poles; Structure of waters; Synchronous machine; | |
| Others : https://iopscience.iop.org/article/10.1088/1757-899X/576/1/012001/pdf DOI : 10.1088/1757-899X/576/1/012001 |
|
| 学科分类:材料科学(综合) | |
| 来源: IOP | |
PDF
|
|
【 摘 要 】
Large-capacity synchronous machines are prone to failure due to their complicated structure. The timely detection and processing in the early stage of the failure can avoid further expansion of the fault and avoid huge economic losses. By studying the structure of water-hydrogen-hydrogen turbine generators, this paper analyzes the types and characteristics of early faults of every component, and provides reference for the operation and state maintenance of synchronous machines.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| Early Faults and Characteristics of Large Capacity Non-salient Pole Synchronous Electric Machines | 440KB |
PDF