2019 2nd International Conference on Advanced Materials, Intelligent Manufacturing and Automation | |
Design of Safety Drive Module for DC Switch Machine without Relay | |
Ren, Xiguo^1^2 ; Ding, Huan^1 ; Han, Shuai^1 ; Ge, Shumin^1 | |
Electrical Engineering, CRSC Research and Design Institute Group Co. Ltd., Beijing | |
100070, China^1 | |
Engineering Physics, Tsinghua University, Beijing | |
100084, China^2 | |
关键词: Centralized control; Control centre; Control command; Current surges; DC switch; Failure safeties; Railway signalling systems; Reliable operation; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/569/3/032070/pdf DOI : 10.1088/1757-899X/569/3/032070 |
|
来源: IOP | |
【 摘 要 】
Aiming at the shortcomings of centralized control in the railway signalling system interiorly. This paper introduces a safety driving module of the DC switch machine, which utilizes the advanced power electronics technology based on the "Failure-Safety" principle and could reach SIL4 level. The module is directly installed in the trackside control cabinet. After receiving the control command of the control centre, the module could ensure safe and reliable operation trackside DC switch machine without relay. At the same time, the module solves the problem of current surge when the DC Switch Machine is starting operation. The module is running stable, strong practicability by experiment. It will play an important role in the distributed trackside control system.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Design of Safety Drive Module for DC Switch Machine without Relay | 523KB | download |