会议论文详细信息
2nd International Conference on Mechanical Engineering and Applied Composite Materials
Magnetic graphene oxide for efficient solid phase extraction of DEHP
机械制造;材料工程
Ma, L.^1 ; Huang, J.^1 ; Zhou, M.^1
Tianhong Measurement Institute, Zhuzhou
412036, China^1
关键词: Analytical performance;    Di-2-ethylhexyl phthalate;    Environmental water samples;    Extraction efficiencies;    Limit of detection;    Optimum conditions;    Solid-phase extraction;    Standard deviation;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/544/1/012063/pdf
DOI  :  10.1088/1757-899X/544/1/012063
来源: IOP
PDF
【 摘 要 】

DEHP (di-2-ethylhexyl phthalate) can cause negative impacts on human health, thus development of reliable analytical methods for the determination of PAEs is important.In this work, magnetic graphene oxide was synthesized and used as the sorbent for solid phase extraction of DEHP. Factors that influence the extraction efficiency of DEHP were studied. The optimum conditions, such as solution pH, extraction time, desorption time, and eluent type and volume were obtained. The analytical performance of the developed method was investigated, and it was found that the limit of detection (LOD) for DEHP was 0.35 μg/L and the related standard deviation (RSD) was 4.3 %. The proposed method was applied in the determination of DEHP in environmental water samples with recoveries of 91.6-106.5%.

【 预 览 】
附件列表
Files Size Format View
Magnetic graphene oxide for efficient solid phase extraction of DEHP 705KB PDF download
  文献评价指标  
  下载次数:23次 浏览次数:26次