【 摘 要 】

Hydrogen bubbling is a typical corrosion morphology caused by hydrogen sulfide corrosion. In order to explore hydrogen sulfide corrosion of iron, the composition of flue gas under actual conditions was simulated in this research. Hydrogen sulfide corrosion in flue gas of four kinds of materials selection of ground process pipeline and underground pipe string was researched experimentally. The pressure and temperature of hydrogen bubbling corrosion morphology under actual flus gas conditions were obtained. The electrochemical corrosion mechanism between iron and hydrogen sulfide was investigated.