1st International Conference on Industrial and Manufacturing Engineering | |
The experimental study of the coolant flow rate of an ethylene glycol-mixed water to the heat transfer rate on the radiator | |
工业技术(总论);机械制造 | |
Manik, T.U.H.S.G.^1 ; Sudrajat, G.^1 ; Sitorus, T.B.^1 | |
Mechanical Engineering, Universitas Sumatera Utara, Medan, Indonesia^1 | |
关键词: Coolant flow rates; Heat transfer rate; Hot fluids; Water entry; Water release; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/505/1/012063/pdf DOI : 10.1088/1757-899X/505/1/012063 |
|
学科分类:工业工程学 | |
来源: IOP | |
【 摘 要 】
This study was conducted to determine the rate of the heat transfer in the radiator. There are two types of hot fluid, namely water and an ethylene glycol-mixed water of 50%. The water entry into the radiator at the temperature of 80°C. The inlet water varied by 0.00000067 m3/s, 0.00013 m3/s, 0.0002 m3/s, and 0.00027 m3/s, and the air release is 1.489 m3/s. The results indicate that the higher the flow of water flowing on the radiator pipe causes a radiator heat transfer rate increase. The best water releases for the radiator test is 0.0002 m3/s. The enhancement of qh increases of 655.26 W or up to 13.06%, qc increases of 402.04 W or 7.57%, Uh increases of 41.3 W/m2K or 11%, Uc increases of 4 W/m2K or 5.67%, and effectivity increases 2.35%.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
The experimental study of the coolant flow rate of an ethylene glycol-mixed water to the heat transfer rate on the radiator | 562KB | download |