1st International Conference on Industrial and Manufacturing Engineering | |
The open cycle simulation of the earth air heat exchanger using computational fluid dynamic | |
工业技术(总论);机械制造 | |
Manik, T.U.H.S.G.^1 ; Simanjuntak, J.S.C.^1 ; Sitorus, T.B.^1 | |
Mechanical Engineering, Universitas Sumatera Utara, Medan, Indonesia^1 | |
关键词: 3D simulations; Earth-air heat exchangers; Earthair heat exchanger (EAHE); Iron pipe; Open cycles; Outlet air; PVC pipes; Three dimensions; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/505/1/012049/pdf DOI : 10.1088/1757-899X/505/1/012049 |
|
学科分类:工业工程学 | |
来源: IOP | |
【 摘 要 】
The purpose of this study is to simulate the fluid flow in a heat exchanger finned ground-air using computational fluid dynamics. The simulation carried out under the velocity of 1 m/s, 2 m/s, and 3 m/s; and the condition of the pipe was restricted to a depth of 2 m from the ground. The simulation was also used for flow, transient, incompressible, turbulent, and three dimensions. The materials that used for the Earth-Air Heat Exchanger (EAHE) is an iron pipe, which has dimension of 3 inches, 2 mm thick pipe, pipe length of 1.2 m and arranged directly with radial fin 17 with each distance of 2 cm and has a thickness of 2 mm, then the pipe was connected with PVC pipe with a length of 2.5 m. The temperature average of the outlet air of the 3D simulation result, using ANSYS, and was obtained 14.52°C inlet air velocity of 1 m/s, at 25.81°C is 2 m/s, and at 25.65°C is 3 m/s. The experimental result show that 26.37°C for the velocity of 1 m/s, at 25.92°C is 2 m/s, and at 25.72 °C is 3 m/s. The average COP value of 0.492, the simulation result for the velocity is 1 m/s, at 0.921 is 2 m/s, and at 0.377 is 3 m/s. Meanwhile, for the experimental result of 0.496 is 1 m/s, at 0887 is 2 m/s, and the velocity of 3 m/s is 0.372.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
The open cycle simulation of the earth air heat exchanger using computational fluid dynamic | 849KB | download |