会议论文详细信息
27th International Cryogenics Engineering Conference and International Cryogenic Materials Conference 2018
Test stand for determination of the heat flux to the cold elements of cryogenic systems in case of the vacuum vessel failure
Kopczynski, A.^1 ; Malecha, Z.^1 ; Polinski, J.^1
WUST Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, Wroclaw, Poland^1
关键词: Atmospheric air;    Cryogenic system;    Design process;    Experimental determination;    Insulating vacuum;    Liquid helium;    Thermal shields;    Vacuum failure;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/502/1/012172/pdf
DOI  :  10.1088/1757-899X/502/1/012172
来源: IOP
PDF
【 摘 要 】

The design process of cryogenic equipment requires sizing of the safety accessories for all enclosures containing cryogenic gas or liquid. The size of the accessories depends on the heat load to the cryogen. Vacuum failure following the ventilation of the insulating vacuum with atmospheric air is often considered as a maximum credible incident. For such case the heat inputs to blank liquid nitrogen and to liquid helium vessels have been experimentally determined by other researchers. Nevertheless, for helium systems elements as an actively cooled thermal shield, with a MLI covered external side and bare internal side, experimental data does not exist. WUST has designed a test stand that allows the experimental determination of the heat flux to the helium vessel, nitrogen vessel and to the thermal shield in case of the accidental break of the vacuum. The paper describes the test stand design and test methodology.

【 预 览 】
附件列表
Files Size Format View
Test stand for determination of the heat flux to the cold elements of cryogenic systems in case of the vacuum vessel failure 485KB PDF download
  文献评价指标  