会议论文详细信息
27th International Cryogenics Engineering Conference and International Cryogenic Materials Conference 2018
Thermodynamic cycle design of a 700W@3K sub-cooled helium refrigerator test facility
Lu, X.F.^1 ; Zhang, Q.Y.^1 ; Zhou, Z.W.^1 ; Zhu, Z.G.^1 ; Chen, A.Y.^1 ; Fu, B.^1 ; Li, S.S.^1
Institute of Plasma Physics, Chinese Academy of Sciences, Hefei
230031, China^1
关键词: Cold compressors;    Design parameters;    Helium refrigerators;    Operation temperature;    Process flows;    Temperature margins;    Temperature test;    Thermodynamic cycle;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/502/1/012120/pdf
DOI  :  10.1088/1757-899X/502/1/012120
来源: IOP
PDF
【 摘 要 】
In order to increase the magnetic field and temperature margin of superconducting magnets, a test facility for a 3K sub-cooled helium refrigerator was proposed to decrease the operation temperature from the saturated helium to the sub-cooled helium. The process flow of 3K sub-cooled helium refrigerator has been analysed, including the 4.5K refrigerator unit and 3K refrigerator unit. Two cold compressors arranged in series have been adapted to decompress pressure to achieved 3K sub-cooled helium. The thermodynamic cycle of the 3K sub-cooled helium refrigerator have been designed, which can provide 2.5kW@4.5K in 4.5K mode or 1.2KW@4.5K + 700W@3K in 3K mode. As the most important port, the design parameters and mechanical test at normal temperature test of cold compressors were shown.
【 预 览 】
附件列表
Files Size Format View
Thermodynamic cycle design of a 700W@3K sub-cooled helium refrigerator test facility 898KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:21次