27th International Cryogenics Engineering Conference and International Cryogenic Materials Conference 2018 | |
Film Boiling Heat Transfer from a Wire to Upward Flow of Liquid Hydrogen: Effect of Wire Diameter | |
Shiotsu, M.^1 ; Shirai, Y.^1 ; Matsumoto, T.^1 ; Fujita, K.^1 ; Iwami, Y.^1 ; Kobayashi, H.^2 ; Nonaka, S.^2 ; Naruo, Y.^2 ; Inatani, Y.^2 | |
Dept. of Energy Science and Technology, Kyoto University, Kyoto, Japan^1 | |
Institute of Space and Astronautical Science, JAXA, Kanagawa, Japan^2 | |
关键词: Film boiling; Forced flows; Liquid hydrogens; New correlations; Subcoolings; Test wires; Upward flow; Wire diameter; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/502/1/012089/pdf DOI : 10.1088/1757-899X/502/1/012089 |
|
来源: IOP | |
【 摘 要 】
Film boiling heat transfer coefficients were measured for the test wires of 0.5 and 0.7 mm in diameters and 200mm in length located at the centre of 8 mm diameter conduit with upward flow of liquid hydrogen. Pressures are ranged from 0.4 to 1.1 MPa, liquid subcoolings from 0 to 11 K and flow velocities up to 5 m/s. The experimental data were compared with the authors' correlation for forced flow film boiling already presented based on the data for 1.2 mm diameter test wire. The experimental data are higher than the predicted values by the correlation. Discussion is made on the effect of wire diameter observed and a new correlation was presented.Published under licence by IOP Publishing Ltd.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Film Boiling Heat Transfer from a Wire to Upward Flow of Liquid Hydrogen: Effect of Wire Diameter | 386KB | download |