会议论文详细信息
27th International Cryogenics Engineering Conference and International Cryogenic Materials Conference 2018
Film Boiling Heat Transfer from a Wire to Upward Flow of Liquid Hydrogen: Effect of Wire Diameter
Shiotsu, M.^1 ; Shirai, Y.^1 ; Matsumoto, T.^1 ; Fujita, K.^1 ; Iwami, Y.^1 ; Kobayashi, H.^2 ; Nonaka, S.^2 ; Naruo, Y.^2 ; Inatani, Y.^2
Dept. of Energy Science and Technology, Kyoto University, Kyoto, Japan^1
Institute of Space and Astronautical Science, JAXA, Kanagawa, Japan^2
关键词: Film boiling;    Forced flows;    Liquid hydrogens;    New correlations;    Subcoolings;    Test wires;    Upward flow;    Wire diameter;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/502/1/012089/pdf
DOI  :  10.1088/1757-899X/502/1/012089
来源: IOP
PDF
【 摘 要 】

Film boiling heat transfer coefficients were measured for the test wires of 0.5 and 0.7 mm in diameters and 200mm in length located at the centre of 8 mm diameter conduit with upward flow of liquid hydrogen. Pressures are ranged from 0.4 to 1.1 MPa, liquid subcoolings from 0 to 11 K and flow velocities up to 5 m/s. The experimental data were compared with the authors' correlation for forced flow film boiling already presented based on the data for 1.2 mm diameter test wire. The experimental data are higher than the predicted values by the correlation. Discussion is made on the effect of wire diameter observed and a new correlation was presented.Published under licence by IOP Publishing Ltd.

【 预 览 】
附件列表
Files Size Format View
Film Boiling Heat Transfer from a Wire to Upward Flow of Liquid Hydrogen: Effect of Wire Diameter 386KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:17次