会议论文详细信息
27th International Cryogenics Engineering Conference and International Cryogenic Materials Conference 2018
Design and thermal calculations of FRESCA2 heat exchangers for pressurised superfluid helium baths temperature controlling
Polinski, J.^1 ; Grabowski, M.^1 ; Chorowski, M.^1 ; Crean, A.V.^2 ; Parma, V.^2
WUST Wroclaw University of Science and Technology, Wroclaw, Poland^1
CERN Organisation Europeen Pour la Recherche Nucleaire, Geneva, Switzerland^2
关键词: Cooling medium;    Pumping speed;    Required time;    Temperature controlling;    Temperature level;    Thermal calculation;    Thermal model;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/502/1/012086/pdf
DOI  :  10.1088/1757-899X/502/1/012086
来源: IOP
PDF
【 摘 要 】

In order to characterise and qualify superconducting cables at currents up to 70 kA, at background magnetic fields up to 13 T and at 1.9 K or 4.3 K temperature levels the Facility for Reception of Superconducting Cable (FRESCA2) is currently under design in collaboration between CERN and WUST. The FRESCA2 design using the double cryostat concept, with superconducting magnet external cryostat and a cable sample insert internal cryostat. The magnet and the cable sample are held in the pressurised superfluid helium bath of the particular cryostat, whose temperature is controlled by a heat exchanger (HX), where the saturated superfluid helium (Hells) is used as the cooling medium. The paper presents the design and the thermal model of the HXs as well as the calculation of their minimum area necessary to cool-down the particular bath from 4.3 K to 1.9 K in the required time in respect to an available pumping speed of warm compressors.Published under licence by IOP Publishing Ltd.

【 预 览 】
附件列表
Files Size Format View
Design and thermal calculations of FRESCA2 heat exchangers for pressurised superfluid helium baths temperature controlling 1190KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:10次