Calculation and position optimization on vapor cooled shield for liquid hydrogen storage
Zheng, Jianpeng^1^2 ; Chen, Liubiao^1 ; Cui, Chen^1 ; Zhou, Yuan^1^2 ; Wang, Junjie^1^2
Chinese Academy of Sciences, Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, China^1
University of Chinese Academy of Sciences, China^2
关键词: Critical temperatures;    Installation position;    Insulation system;    Liquid hydrogen storage;    Liquid hydrogens;    Low temperatures;    Multi-layer insulation;    Optimal position;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/502/1/012080/pdf
DOI  :  10.1088/1757-899X/502/1/012080
来源: IOP
PDF
【 摘 要 】

The ZBO (zero boil off) storage of liquid hydrogen (LH2) has broad prospects in aerospace and civil market. Because of low critical temperature and volatility, LH2 tank poses severe requirements to the insulation system (multilayer insulation (MLI) is considered to be the most promising). In order to reduce heat leak into tank, vapor cooled shield (VCS) was set up to cool the MLI by retrieving the cold energy of discharged low temperature GH2. In this study, a simplified physical model is established to investigate the optimal position of VCS in MLI, and the influence of various factors on the performance of VCS has been analysed. Taking the minimum heat leak as the target, the best installation position is around 50% in MLI (inside looking outward) for the given condition. The heat leak of the tank can be reduced by 48.03% at most.Published under licence by IOP Publishing Ltd.

【 预 览 】
附件列表
Files Size Format View
Calculation and position optimization on vapor cooled shield for liquid hydrogen storage 1033KB PDF download
  文献评价指标  
  下载次数:14次 浏览次数:15次