会议论文详细信息
27th International Cryogenics Engineering Conference and International Cryogenic Materials Conference 2018
Development and Experimental Investigations on Two Stage GM Type Pulse Tube Refrigerator for 20 K Applications
Gujarati, P.B.^1 ; Desai, K.P.^1 ; Naik, H.B.^1 ; Atrey, M.D.^2
S v National Institute of Technology, Surat
395007, India^1
Indian Institute of Technology Bombay, Mumbai
400076, India^2
关键词: Cooling performance;    Experimental investigations;    High reliability;    Moving components;    Optimum frequency;    Pulse tube refrigerators;    Regenerative materials;    Regenerator matrices;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/502/1/012026/pdf
DOI  :  10.1088/1757-899X/502/1/012026
来源: IOP
PDF
【 摘 要 】

Because of the absence of any moving components at the cold region, low vibration and high reliability, two stage GM type pulse tube refrigerator (PTR) is nowadays preferred compared to conventional GM refrigerator for cooling of superconducting magnets, SQUIDs, and cryopumping applications. The second stage regenerative material plays an important role in achieving low temperature below 20 K. Leads balls with 0.2 mm to 0.4 mm average diameter was selected as second stage regenerator matrix material while 200 mesh of SS 304 material was filled in the first stage. A two stage GM type PTR was developed. A rotary valve was fabricated and the valve timing effects on cooling performance of PTR were also studied. The valve timings were varied by the different width of rotor slit forming the flow area with stator ports. The lowest no-load temperature of 18.52 K and cooling capacity of 7 W at 29.58 K were obtained with an optimum frequency of 1.6 Hz, charging pressure of 16.5 bar.

【 预 览 】
附件列表
Files Size Format View
Development and Experimental Investigations on Two Stage GM Type Pulse Tube Refrigerator for 20 K Applications 765KB PDF download
  文献评价指标  
  下载次数:18次 浏览次数:17次